XS.8.25.DA.57T5

XS.8.25.DA.57T5

Classification : Ex e II T5 Gb – Ex II 2G.
Locking power off, the internal return spring keeping the bolt out. This product is compliant with EN 60079-0 and EN 60079-1 regulations. It is used for locking doors, machine guards or various mechanisms in explosive atmospheres (Gas only). No monitoring position contact included in this product

  • Standard voltage : 24Vdc
  • Voltage range : 12 to 48Vdc
  • Power Consumption w) : 17W (permanent service)
  • Position monitoring : No
  • Return spring : internal
  • Input and output force (N) : 10
  • Protection rating EN 60 529 : IP 65
  • Temperature rating : B
  • Service operating temperature : – 5° C, + 40° C
  • According to standards : EN 60079-0, EN 60079-1

Other Info

  • Ref : XS825DA57T5
  • Use : Locking power off
  • Supply : Direct current
  • Stroke (mm) 15
  • Maximum radial force (daN) 400
  • Space envelope (mm) : 65 x 106 x 150,5
  • Domains : Automation – Industry, Building security